Brand Name :TIANAN Electric
Model Number :DFT6-12
Certification :ISO9001:2000, VDE, CCC
Place of Origin :CHINA
MOQ :1set
Price :Pending
Payment Terms :L/C, T/T, D/P, D/A
Supply Ability :2000sets per year
Delivery Time :40 work days
Packaging Details :Nude
Rated Voltage :12KV
Structure :Open frame
Size :1 Uint
Rated Current :630A
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

11kV Outdoor RMU Cable Branch Box For power acceptance and distribution​

Overview

DFT6-12/24 series is the new power supply equipment that we design for coordinating 10kV/24kV power Open Frame 11kV Compact Transformer Substation , Outdoor Cable Branch Boxnetwork cable system.

It is suitable at the cable node place in 10 kV/24kV system,as the electric energy accepts and distributing.The cable conveys the electric energy, used in outdoor with the cable circuit to connect and breakout, branch and continues or changes.
Service condition
A. Altitude 1000m (above sea level);
B. Ambient temperature: -25ºC~+40ºC;
C. Wind speed 34m/s
D. The spot should have no regularly exquisite shake.

Main technical data
Main parameter of FN26-12/24 S
F6 load switch

Item Unit Parameter Parameter
Rated voltage kV 12 24
Rated current A 630 630
Rated short time withstand current kA/s 25/2 25/2
Rated peak withstand current kA 63 63
Rated short circuit making current kA/times 50/2 63/2
1 min power frequency withstand voltage kV 42 65
Lightning impulse withstand voltage kV 75 125
Mechanical life Times 10000 10000
SF6 gas pressure(surface pressure in 20ºC) Mpa 0.04 0.04
Yearly gas leakage rate 1% 1%


Main technical parameter of cable connector

Item Unit Parameter Parameter
Rated voltage kV 12 24
Rated current A 630 and below 630 and below
Cross section of cable mm2 25~400 35~400
Resistance in connection point μΩ 40 45
Partial discharge pC/kV 10/13 10/21.5
Rated short time withstand current kA/s 20/3 25/2
Rated peak withstand current kA 50 63
1 min power frequency withstand voltage kV 42 65
Lightning impulse withstand voltage kV 75 125